Lumbar discectomy is an effective therapy for neurological decompression in patients suffering from sciatica due to a herniated nucleus pulposus (NP). However, high numbers of patients suffering from persisting postoperative low back pain have resulted in many strategies targeting the regeneration of the NP. For successful regeneration, the stiffness of scaffolds is increasingly recognized as a potent mechanical cue for the differentiation and biosynthetic response of (stem) cells. The aim of the current study is to characterize the viscoelastic properties of the NP and to develop dense collagen scaffolds with similar properties. The scaffolds consisted of highly dense (0.5%-12%) type I collagen matrices, prepared by plastic compression. The complex modulus of the NP was 22 kPa (at 10 rad s-1), which should agree with a scaffold with a collagen concentration of 23%. The loss tangent, indicative of energy dissipation, is higher for the NP (0.28) than for the scaffolds (0.12) and was not dependent of the collagen density. Gamma sterilization of the scaffolds increased the shear moduli but also resulted in more brittle behavior and a reduced swelling capacity. In conclusion, by tuning the collagen density, we can approach the stiffness of the NP. Therefore, dense collagen is a promising candidate for tissue engineering of the NP that deserves further study, such as the addition of other proteins.

doi.org/10.1002/jor.20789
J. Orthop. Res.
Biological Soft Matter-Former Group